Title: Investigate EC dangerous substance failure at R18A007 for 1994 : final draft report
Author: Rob Hocking
Document Type: Monograph
Annotation: EA additional title info: November 1996
Abstract:
The St. Austell River at Molingey Gauging Station (R18A007) failed the Environmental Quality Standard (EQS) for Dieldrin on 31st October 1994. The failure coincided with high rainfall on the day (30mm) and high BOD's at both the gauging station and Pentewan Bridge
(R18A008) which is located downstream. No other Dieldrin data was collected that day. Commercial property has been developed on an area once used as a joinery near St. Austell. The objective of this report is to determine the cause of the EC Dangerous Substance Directive EQS failure in the St. Austell River at the monitoring site R18A007.
Publisher: Environment Agency
Publication Date: 1996
Publication Place: Bodmin
Subject Keywords: Environmental quality; Water quality; Rivers; Insecticides; Dangerous substances; Directive on Dangerous Substances; Directives (European Union)
Geographic Keywords: EA South West; West Cornwall and the Fal catchment
Extent: n.p. [7]
Permalink: http://www.environmentdata.org/archive/ealit:1526
Total file downloads: 315
Download PDF Display PDF in separate tab