Title: 
Wensum Demonstration Test Catchment's Monitoring kiosk F

Related Party - Organisation (Author): Wensum Alliance
Abstract:
The Wensum DTC’s monitoring kiosk F contains several different sets of monitoring equipment measured at 30 minute resolution. The YSI 6600 multi-parameter sonde measures temperature, turbidity, electrical conductivity, chlorophyll-a, pH and dissolved oxygen. Stage height is measured by a pressure transducer housed in a stilling well. Flow is estimated by a Doppler flow meter, the Sontek Argonaut. Analogues (nutrients) are measured which include total phosphorus and total reactive phosphorus using a Hach Lange Phosphax Sigma analyser, nitrate is measured using a Nitratax SC optical probe. Further information regarding monitoring equipment is available in the supporting documentation. Water samples are laboratory analysed from our monitoring points at a lower resolution. The laboratory measurements can include major ions, phosphorus and nitrogen fractions, alkalinity, pH and more. Monitoring kiosks also contain ISCO automatic samplers often triggered during storm events to capture hydrochemical parameters of storm water at high resolution.

Subject Keywords: Stage heightFlow rateWater temperatureElectrical conductivityWater pHAmmoniumTurbidityChlorophyllsNitratesAlkalinityPhosphorusElementsCarbonOxygenWater samplingWater quality measurementsWater qualityWater levels
Geographic Keywords: WensumNorfolkEast AngliaUnited KingdomCatchment basin
Phenomenon Time -  Start Date/Time: 2011-03-01 00:00:00 End Date/Time:  2015-01-31 08:35:00

Geographic Extent -
    Longitude (West): 1.1294186
    Longitude (East): 1.1694186
    Latitude (South): 52.767171
    Latitude (North): 52.797171

Data Quality Statement:
The Wensum DTC has a monitoring network installed to measure meteorological, hydrological and hydrochemical parameters in target sub-catchments. This statement aims to describe the in-situ monitoring equipment, methods and protocols performed on our data before it is published on the archive. Quality assurance and quality control procedures Quality assurance (QA) procedures are followed during data collection, detailed with our monitoring equipment. Regular maintenance activities are carried out at a weekly frequency and involve cleaning of flow-through cells, clearing of in-channel vegetation and debris where stage is monitored and cleaning of rain gauges. All field work and maintenance activities are entered into maintenance logs for each site, which are used during data quality control (QC) procedures. QC procedures include the validation of high-frequency nutrient data using point samples in the Blackwater sub catchment. These samples are analysed in laboratories following standard methods. Inter-laboratory comparisons are used to check consistency in analytical procedures between sub-catchments. QC procedures also include the identification of errors in all data sets. Errors flagged as critical include: periods of maintenance when data may be unrepresentative; equipment of power failures; or data below limits of detection. On-site visits by field staff are recorded in a maintenance log which is checked against the data during the quality control (QC) post-processing. Any data likely to be disturbed by the routine field work are removed, along with any known periods of downtime, hence some of the data is not included and there may be time breaks in the files accessible on the archive. The Wensum DTC’s sampling kiosks monitor many hydrochemical parameters at a 30 minute resolution. Samples are also analysed less frequently at the University of East Anglia’s laboratory, all using standard laboratory methods. The monitoring equipment used is detailed below: Pressure transducer – Measures stage height. Sontek Argonaut – Doppler meter which measures stage height and infers flow from velocity and pre-programmed stream cross section. Sontek IQ – Doppler meter which measures stage height and infers flow from velocity and pre-programmed stream cross section. YSI 6600 series multi-parameter sonde - Measures water temperature, electrical conductivity, dissolved oxygen, pH, ammonium, turbidity and chlorophyll-a. Hach Lange Nitratax SC optical probe which measures N concentration. The Nitratax sensors are calibrated every 3 months using a standard solution. Hach Lange Sigmatax and Phosphax Sigma analyser (kiosk E and F only) - Measures total phosphorus and total reactive phosphorus colorimetrically using homogenised sample from Sigmatax. The Phosphax Sigma is automatically cleaned and calibrated daily using reagents that are replaced every 3 months. Routine laboratory water sample data Water samples are collected at the monitoring kiosk’s intake pipes and are analysed at the University of East Anglia’s laboratory using standard laboratory practices. ISCO water sample data Automatic ISCO samplers are installed at monitoring kiosks to measure hydrochemical properties of storm derived water. These are analysed at the University of East Anglia.
Documentation: Wensum DTC General information - Supporting Document Monitoring Kiosk F
Publication Date: 
2015-11-13


To discuss any issues relating to this dataset please either send an email to dis@fba.org.uk or post to our forum

Download All 5.3MB

All Version Downloads

Rights Statement

This data is published under the licence FBA Licence

Attribution: Wensum Alliance

Citation of this data should be as follows:
Wensum Alliance (2015): Wensum Demonstration Test Catchment's Monitoring kiosk F. Version:1. [dataset] Freshwater Biological Association [publisher]. doi:10.17865/dtcwensum63

Total file downloads: 1328

Data ComponentsProjects/Activities

Measurements
Analogue (nutrient), YSI, turbidity and stage data for the Wensum Demontration Test Catchment's monitoring kiosk F in 2011DownloadCSV1.05MB
Analogue (nutrient), YSI, turbidity and stage data for the Wensum Demontration Test Catchment's monitoring kiosk F in 2012DownloadCSV1.31MB
Analogue (nutrient), YSI, turbidity and stage data for the Wensum Demontration Test Catchment's monitoring kiosk F in 2013DownloadCSV1.29MB
Analogue (nutrient), YSI, turbidity and stage data for the Wensum Demontration Test Catchment's monitoring kiosk F in 2014DownloadCSV1.29MB
ISCO automatic water sample data for the Wensum Demonstration Test Catchment's Kiosk FDownloadCSV0.05MB
Routine laboratory water sample data for the Wensum Demonstration Test Catchment's monitoring kiosk FDownloadCSV0.05MB

Supplementary Files
Wensum DTC General information - Supporting Document Monitoring Kiosk FDownloadPDF0.27MB