Skip to main content

Dataset


  • Version 1 of 1


Dataset

Title: 
Thackthwaite Beck Automatic Weather Station Dataset

Related Party - Individual (Project Scientist): Doctor Gareth Owen (Newcastle University) Email address: gareth.owen1@ncl.ac.uk
Related Party - Organisation (Deliverer): EdenDTC
Abstract:
Thackthwaite Beck Catchment AWS (Environmental Measurements Ltd) - measuring rainfall, net solar radiation, relative humidity, wind speed, wind direction - 15 minute resolution. Please refer to supplementary document for QC information.

Subject Keywords: WeatherRainfallWind directionRelative humidityWind speedNet solar radiationAir temperature
Geographic Keywords: Eden (river, Cumbria)CumbriaEngland
Phenomenon Time -  Start Date/Time: 2011-05-06 11:00:00 End Date/Time:  2016-04-11 12:00:00

Geographic Extent -
    Longitude (West): -2.895
    Longitude (East): -2.894
    Latitude (South): 54.603
    Latitude (North): 54.604

Data Quality Statement:
Data collection in the EdenDTC project is subjected to rigorous Quality Assurance (QA) and Quality Control (QC) procedures. QA is carried out to ensure that accurate, reliable data is recorded in the field – this involves periodic maintenance of the site (e.g., vegetation removal, checking channel cross-sections for physical changes), and the downloading, maintenance and calibration (where necessary) of monitoring instruments (principally rain gauges, stream gauges, automatic weather stations, and water quality monitoring equipment). The calibration of in-situ water quality monitoring equipment is carried out by trained technical staff, according to the manufactures specifications. All field work and maintenance activities are entered into maintenance logs for each site, which are used during data quality control (QC) procedures. QC is implemented on all data after its collection, the method of which varies according to the environmental variable in question. The overall goal is to ensure that data are accurate and representative. In-situ water quality data (measured chiefly by YSI multi-parameter sondes, Hach Lange nitrate and phosphorus analysers, and turbidity sensors) are cross-referenced with manually collect water samples, which are analysed in a certified laboratory using reference analytical methods (this is particularly relevant for nutrient and suspended sediment determinands). QC also includes the identification of errors in all data sets (due to equipment or Thackthwaiteer failures, data below limits of detection, instrument drift, etc.). Data known as being non-representative and/or including errors is manually flagged as ‘critical’ and is subsequently removed from the series. Copies of the QC error code files can be found for each piece of monitoring equipment. Any adjustments made to data (e.g., time stamp correction, systematic concentration step-change) will be detailed in a separate document found with a specific site/instrument.
Publication Date: 
2016-07-19


To discuss any issues relating to this dataset please either send an email to dis@fba.org.uk or post to our forum

Download All 10MB

All Version Downloads

Rights Statement

This data is published under the licence FBA Licence

Attribution: EdenDTC

Citation of this data should be as follows:
EdenDTC (2016): Thackthwaite Beck Automatic Weather Station Dataset. Version:1. [dataset] Freshwater Biological Association [publisher]. doi:10.17865/dtceden180

Total file downloads: 292

Data ComponentsProjects/Activities